quality by EDP

Kompetenz rund um´s

Home Über EDP Kontakt Partner Referenzen Impressum

Sitemap

BarcodeLabel für Datenträger
Datenträger
BarcodeLabel
DC / LTO Analyser
Datenträger-Archivierung
Intelligentes
Datenmanagement
Datenträger-Vernichtung
Rechenzentrum / IT-Raum
19" Racks

Stromverteilerleisten / PDU
Basic PDU
Basic PDU
Rack Monitoring System
RMS
Server Technology PDU
Metered PDU
Smart PDU
Smart POPS/PIPS PDU

Switched PDU
Switched POPS PDU
Racküberwachung EMCU

Sentry Power Manager
Smart Power Monitor
Fail-Safe Transfer Switch
APC PDU
Basic PDU
Metered PDU
Switched PDU
Metered-by-PDU
Avocent PDU
PM 1000
PM 2000
PM 3000
APC InfraStruXure
IT Infrastruktur Management
DeTwo
Digital KVM Extension
USV-Anlagen
Airflow-Management
Patchkabel
Computerleitstände

Stromverteilerleisten / PDU (Power Distribution Unit) Switched PDU

[ IT-Products by EDP - Alles aus einer Hand ]


Server Technology Switched PDU

Die netzwerkfähige (TCP/IP) Switched PDU (Power Distribution Unit - schaltbar), also Strom- oder Steckdosenleisten, messen die Stromlast und zeigen sie auf dem Display an, und zwar für jede Phase einzeln.

Jeder einzelne Steckplatz lässt sich über per Fernzugriff ein- und ausschalten. Es werden Meldungen per SNMP oder Email generiert und informieren über die Zustände und Abweichungen von eingestellten Werten für Strom, Temperatur und Luftfeuchte. Der Zugriff mit jedem Web-Browser ist ebenfalls möglich.

Sie können einphasig (16 oder 32 A) oder dreiphasig 3x16 oder 3x32 A) und sind mit den Kaltgeräte-Steckdosentypen IEC 320 C13 und C19 bestückt. Wobei C19 Anschlüsse häufig für stärkere Verbraucher gedacht sind, wie beispielsweise für Blade Server.

Artikel-Nr. Beschreibung Maße in mm HE Preis
LE-CW-8HEA211 PDU Switched; 1U, 8 x IEC C13 Outlets, Input Amp Meter, 230V 16A w/ IEC 60320 C20 Inlet, 2 x Temp/Humid Capable, Fuse Branch Circuit Protection (Input power cord ordered separately); Expansion / Slave Part no. CX-8HEA211 437x432x44
(LxTxH)
1 anfragen
LE-CW-8HEK211 PDU Switched; 1U, 8 x IEC C13 Outlets, Input Amp Meter, 230V 32A w/ IEC 60320 C20 Inlet, 2 x Temp/Humid Capable, Fuse Branch Circuit Protection; Expansion / Slave Part no. CX-8HEK211 437x432x44
(LxTxH)
1 anfragen
LE-CW-16HEA452 PDU Switched; 2U, 16 x IEC C13 Outlets, Input Amp Meter, 230V 16A w/ IEC C20 Inlet (Front Cord Entry), 20 A Circuit Breakers, 2 x Temp/Humid Capable (Input power cord sold separately); Expansion / Slave Part no. CX-16HEA452 432x432x89
(LxTxH)
2 anfragen
LE-CW-16HEK452 PDU Switched; (Expansion Unit) 2U, 16 x IEC C13 Outlets, Input Amp Meter, 230V 32A w/ IEC 60309 Connector, 3m (10ft) Cord (Front Cord Entry), 20 A Circuit Breakers; Expansion / Slave Part no. CX-16HEK452 432x432x89
(LxTxH)
2 anfragen
LE-CW-16VE-C20M PDU Switched; 0U; 16 x IEC C13 Outlets; 230v 16a; LED amp meter;
C20 Inlet; 2 x Temp-Humid Capable; Expansion / Slave Part no. CX-16VE-C20M
1257x29HE (LxH) 29 anfragen
LE-CW-16VE-C20MX PDU Switched; 0U; 16 x IEC C13 Outlets; LED amp meter; 230V 16A input w- C20 inlet; 2 x Temp-Humid Capable; Expansion / Slave Part no. CX-16VE-C20MX 1257x29HE (LxH) 29 anfragen
LE-CW-16VE-P16M PDU Switched; 0U; 16 x IEC C13 Outlets; LED amp meter; 230V 16A input w- 30916 connector & cord; 10'; 2 x Temp-Humid Capable; with retractable fuses; Expansion / Slave Part no. CX-16VE-P16M 1257x29HE (LxH) 29 anfragen
LE-CW-16VE-P32M PDU Switched; 0U; 16 x IEC C13 Outlets; LED amp meter; 230V 32A input w- 30932 connector & cord; 10'; 2 x Temp-Humid Capable; with retractable fuses; Expansion / Slave Part no. CX-16VE-P32M 1257x29HE (LxH) 29 anfragen
LE-CW-24V4J411 PDU Switched; 24 x IEC C13 outlets; 3 x LED Amp meter; 230-400V 3 phase; 16A IEC 60309 w- circuit breaker protection; std module layout; front power cord entry; 2 x Temp-Humid capable; Expansion / Slave Part no. CX-24V4J411 1753x40HE (LxH) 40 anfragen
LE-CW-24V4K411 PDU Switched; 24 x IEC C13 outlets; 3 x LED Amp meter; 230-400V 3‐phase; 32A IEC60309 (5 pin Pin-Sleeve Red ground at 6 o'clock); circuit breaker protection; std module layout; front power cord entry; 2 x Temp-Humid Capable; Expansion / Slave Part no. CX-24V4K411 1753x40HE (LxH) 40 anfragen
LE-CW-24VEA311A1 PDU Switched; 0U; 18 x IEC C13 Outlets and 6 x IEC C19 Outlets; 3 x LED Amp Meters; 230V 16A Input w- IEC C20 Inlet; Bottom/Front Cord Entry; 2 x Temp/Humid Capable; with Retractable Fuses; Expansion / Slave Part no. CX-24VEA311A1 1753x40HE (LxH) 40 anfragen
LE-CW-24VE-C20M PDU Switched; 0U; 24 x IEC C13 Outlets; 3 x LED Amp Meters; 230V 16A input w- C20 Inlet; 2 x Temp/Humid Capable; with retractable Fuses; Expansion / Slave Part no. CX-24VE-C20M 1753x40HE (LxH) 40 anfragen
LE-CW-24VEK311A1 PDU Switched; 0U; 18 x IEC C13 Outlets and 6 x IEC C19 Outlets; 3 x LED Amp Meters; 230V 32A Input w- IEC 60309 Connector; Bottom-Front Cord Entry; 3m (10') Cord; 2 x Temp-Humid Capable; with Retractable Fuses; Expansion / Slave Part no. CX-24VEK311A1 1753x40HE (LxH) 40 anfragen
LE-CW-24VE-P32M PDU Switched; 0U; 24 x IEC C13 Outlets; 3x LED amp meter; 230V 32A
input w- 30932 connector & cord; 10'; 2 x Temp-Humid Capable; with retractable Fuses; Expansion / Slave Part no. CX-24VE-P32M
1753x40HE (LxH) 40 anfragen
LE-CW-32VDE-30932E PDU Switched; 0U; 32 x IEC C13 Outlets; LED amp meter; 2 x 230V 32A
input w- L30932 connector & cord; 10'; 2 x Temp-Humid Capable; Expansion / Slave Part no. CX-32VDE-30932E
1270x29HE (LxH) 29 anfragen
LE-CW-32VDE-C20 PDU Switched; 0U; 32 x IEC C13 Outlets; LED amp meter; 2 x 230V 16A
input w- C20 Inlet; 2 x Temp-Humid Capable; Expansion / Slave Part no. CX-32VDE-C20
1270x29HE (LxH) 29 anfragen
Downloads
Broschüre Server Technology

Nach oben